6 - 33
6. PARAMETERS
No. Symbol
Name and function
Initial
value
Unit
Setting
range
PD03
*DIA3 Input signal automatic ON selection 3
Select the input devices to be automatically turned ON.
part is for manufacturer setting. Do not set the value by any means.
0
Initial value
BIN
HEX
Device name
0
Automatic/manual
selection (MD0)
0
0
0
0 0 0
BIN 0: Used in CC-Link or as external
input signal.
BIN 1: Automatic ON
0000h Refer
to
name and
function
column.
PD04
*DIA4 Input signal automatic ON selection 4
Select the input devices to be automatically turned ON.
0
0
Initial value
BIN
HEX
Device name
Point table No.
selection 2 (DI1)
0
BIN 0: Used in CC-Link or as external
input signal.
BIN 1: Automatic ON
0
0
Point table No.
selection 1 (DI0)
Point table No.
selection 3 (DI2)
Point table No.
selection 4 (DI3)
0
0
Initial value
BIN
HEX
Device name
Point table No.
selection 6 (DI5)
0
0
0
Point table No.
selection 5 (DI4)
Point table No.
selection 7 (DI6)
Point table No.
selection 8 (DI7)
0 0
0000h Refer
to
name and
function
column.
PD05
For manufacturer setting
Do not change this value by any means.
0000h
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...