3 - 1
3. CC-LINK COMMUNICATION FUNCTIONS
3. CC-LINK COMMUNICATION FUNCTIONS
3.1 Communication specifications
POINT
This servo is equivalent to a remote device station.
For details of the programmable controller side specifications, refer to the CC-Link system master unit manual.
Item Specifications
Power supply
5VDC supplied from servo amplifier
CC-Li
nk
Applicable CC-Link version
Ver.1.10
Communication speed
10M/5M/2.5M/625k/156kbps
Communication system
Broadcast polling system
Synchronization system
Frame synchronization system
Encoding system
MRZI
Transmission path format
Bus format (conforming to EIA RS485)
Error control system
CRC (X
16
+X
12
+X
5
+1)
Connection cable
CC-Link Ver.1.10-compliant cable (Shielded 3-core twisted pair cable)
Transmission format
Conforming to HDLC
Remote station number
1 to 64
(Note)
Cable
length
Communication speed
156Kbps
625Kbps
2.5Mbps
5Mbps
10Mbps
Maximum overall cable length
1200m
900m
400m
160m
100m
Inter-station cable length
0.2m or more
Number of servo amplifiers connected
Max. 42 (when 1 station is occupied by 1 servo amplifier), (max. 32 when 2
stations are occupied by 1 servo amplifier), when there are only remote
device stations. Can be used with other equipment.
Note. If the system comprises of both CC-Link Ver.1.00- and Ver.1.10-compliant cables, Ver.1.00 specifications are applied to the
overall cable length and the cable length between stations. For more information, refer to the CC-Link system master/local unit
user's manual.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...