6 - 30
6. PARAMETERS
6.3.6 Software limit
A limit stop using a software limit (parameter No.PC31 to PC34) is made as in stroke end operation. When a
motion goes beyond the setting range, the motor is stopped and servo-locked. This function is made valid at
power-on but made invalid during home position return. This function is made invalid when the software limit
setting is the same as the software limit setting. A parameter error (A37) will occur if the software limit
setting is less than the software limit setting.
Current position
Unmovable
Movable
Movable area
Software limit
Inhibited area