16 - 4
16. INDEXER POSITIONING OPERATION
(2) When 2 stations are occupied
RXn/RYn: 64 points each, RWrn/RWwn: 8 points each
Programmable controller
Servo amplifier (RYn)
Servo amplifier
Programmable controller (RXn)
(Note)
Device No.
Device name
(Note)
Device No.
Device name
RYn0 Servo-on
RXn0 Ready
RYn1 Start
RXn1 In
position
RYn2 Rotation
direction
specifying
RXn2 Rough
match
RYn3
RXn3
Home position return completion
to
Not available
RXn4
Limiting torque
RYn5
RXn5 Not
available
RYn6
Operation mode selection 1
RXn6
Electromagnetic brake interlock
RYn7
Operation mode selection 2
RXn7
Not available
RYn8
Monitor output execution demand
RXn8
Monitoring
RYn9
Instruction code execution demand
RXn9
Instruction code execution completion
RYnA
Next station selection 1
RXnA
Warning
RYnB
Next station selection 2
RXnB
Battery warning
RYnC
Next station selection 3
RXnC
Movement completion
RYnD
Next station selection 4
RXnD
Dynamic brake interlock
RYnE
Next station selection 5
RXnE
RYnF
to Not
available
to Not
available
RX(n
1)F
RY(n
1)F
RX(n
2)0 Position command execution completion
RY(n
2)0 Position command execution demand
RX(n
2)1 Speed command execution completion
RY(n
2)1 Speed command execution demand
RX(n
2)2 Station
output 1
RY(n
2)2 Not available
RX(n
2)3 Station
output 2
RY(n
2)3 Next station selection 6
RX(n
2)4 Station
output 3
RY(n
2)4 Next station selection 7
RX(n
2)5 Station
output 4
RY(n
2)5 Next station selection 8
RX(n
2)6 Station
output 5
RY(n
2)6 Internal torque limit selection
RX(n
2)7 Station
output 6
RY(n
2)7 Proportion
control
RX(n
2)8 Station
output 7
RY(n
2)8 Gain switching
RX(n
2)9 Station
output 8
RY(n
2)9 Not available
RX(n
2)A
RY(n
2)A Position/speed specifying system selection
to
Not available
RY(n
2)B Not available
RX(n
3)9
RY(n
2)C Speed selection 1
RX(n
3)A Trouble
RY(n
2)D Speed selection 2
RX(n
3)B Remote station communication ready
RY(n
2)E Speed selection 3
RX(n
3)C
RY(n
2)F
to
Not available
to Not
available
RX(n
3)F
RY(n
3)9
RY(n
3)A Reset
RY(n
3)B
to Not
available
RY(n
3)F
Note. "n" depends on the station number setting.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...