5 - 61
5. OPERATION
(2) Replacement procedure
MR-J3BTCBL03M
CN4
CN2
MR-J3BAT
for backup
Old MR-J3BAT
New MR-J3BAT
Servo amplifier
Step 1
Connect MR-J3BAT for backup to the battery connector of
MR-J3BTCBL03M.
MR-J3BTCBL03M
CN4
CN2
MR-J3BAT
for backup
Servo amplifier
Old MR-J3BAT
New MR-J3BAT
Step 2
Remove old MR-J3BAT from the servo amplifier.
MR-J3BTCBL03M
CN4
CN2
MR-J3BAT
for backup
Servo amplifier
New MR-J3BAT
Step 3
Mount new MR-J3BAT to the servo amplifier.
Then, connect the lead wire plug of MR-J3BAT to the C4
connector of the servo amplifier.
CN4
CN2
MR-J3BAT
for backup
MR-J3BTCBL03M
Servo amplifier
New MR-J3BAT
Step 4
Remove the MR-J3BAT for backup from the battery
connector of MR-J3BTCBL03M, and the procedure is
completed.