3 - 9
3. CC-LINK COMMUNICATION FUNCTIONS
3.5 I/O signals (I/O devices) transferred to/from the programmable controller CPU
3.5.1 I/O signals (I/O devices)
The input signals (input devices) may be used as either the CC-Link or CN6 external input signals. Make
selection in parameter No.PD06 to PD11, PD12 and PD14. The output signals (output devices) can be used as
both the CC-Link CN6 external output signals.
POINT
In the factory-shipped status, the forward rotation stroke end (LSP), reverse
rotation stroke end (LSN) and proximity dog (DOG) are valid as the CN6
external input signals.
(1) When 1 station is occupied
RYn/RXn: 32 points each, RWrn/RWwn: 4 points each
Programmable controller
Servo amplifier (RYn)
Servo amplifier
Programmable controller (RXn)
(Note)
Device No.
Signal name
Signal
abbreviation
CN6
connector
pin No.
(Note)
Device No.
Signal name
Signal
abbreviation
CN6
connector
pin No.
RYn0 Servo-on
SON
RXn0 Ready
RD
14
RYn1 Forward
rotation
start
ST1
RXn1 In
position
INP
RYn2 Reverse
rotation
start
ST2
RXn2 Rough
match
CPO
RYn3
Proximity dog
DOG
2
RXn3
Home position return completion
ZP
16
RYn4
Forward rotation stroke end
LSP
3
RXn4
Limiting torque
TLC
RYn5
Reverse rotation stroke end
LSN
4
RXn5
Reserved
RYn6 Automatic/manual
selection
MDO
RXn6 Electromagnetic
brake
interlock
MBR
RYn7 Temporary
stop/Restart
TSTP
RXn7 Temporary
stop
PUS
RYn8
Monitor output execution demand
MOR
RXn8
Monitoring
MOF
RYn9
Instruction code execution demand
COR
RXn9
Instruction code execution
completion
COF
RYnA
Point table No. selection 1
DI0
RYnB
Point table No. selection 2
DI1
RXnA
Warning
WNG
RYnC
Point table No. selection 3
DI2
RXnB
Battery warning
BWNG
RYnD
Point table No. selection 4
DI3
RXnC
Movement completion
MEND
RYnE
Point table No. selection 5
DI4
RXnD
Dynamic brake interlock
DB
RYnF Clear
CR
RXnE Position
range
output
POT
RY(n
1)0
RXnF Reserved
to Reserved
RX(n
1)0
RY(n
1)9
to
Reserved
RY(n
1)A Reset
RES
RX(n
1)9
RY(n
1)B
RX(n
1)A Trouble
ALM
15
to Reserved
RX(n
1)B
Remote station communication
ready
CRD
RY(n
1)F
RX(n
1)C
to
Reserved
RX(n
1)F
Programmable controller
Servo amplifier (RWwn)
Servo amplifier
Programmable controller (RWrn)
Address No.
Signal name
Address No.
Signal name
RWwn
Monitor 1
RWrn
Monitor 1 data
RWwn
1 Monitor
2
RWrn
1 Monitor
2
data
RWwn
2 Instruction
code
RWrn
2 Respond
code
RWwn
3 Writing
data
RWrn
3 Reading
data
Note. "n" depends on the station number setting.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...