16 - 1
16. INDEXER POSITIONING OPERATION
16. INDEXER POSITIONING OPERATION
POINT
To execute the indexer positioning operation, parameter needs to be
changed. Set the parameter No.PA01 to "1
".
The indexer positioning operation is available with servo amplifiers with
software version A6 or later.
This chapter provides the indexer positioning operation method using MR-J3- T servo amplifier. Any matters
not described in this chapter are the same as those of the point table positioning operation. For more
information, refer to chapters up to 15.
16.1 Function
16.1.1 Overview
Using the next station selection 1 (RYnA) to the next station selection 8 (RY(n 2)5) devices, stations from
No.0 to No.254 can be specified.
Settings of servo motor speed and acceleration/deceleration time constant are carried out by specifying the
point table number from 1 to 8 using the speed selection 1 (RY(n 2)C) to the speed selection 3 (RY(n 2)E)
devices. Speed command data can be directly specified by using the remote register when two stations are
occupied.
16.1.2 Servo amplifier standard specifications (functions only)
Item
Description
Command
system
Station command
input
Available with CC-Link communication
CC-Link communication (1 station occupied): 31 stations
CC-Link communication (2 stations occupied): 255 stations
Speed
command
input
Remote
register
Available with CC-Link communication (2 stations occupied)
Set the speed command data (speed) by the remote register.
Speed
No. input
Select a speed and acceleration/deceleration time constant by the point table
Operat
ion m
ode
Automatic
operation
mode
Rotation direction
specifying indexer
Positioning operation is executed to the set station. Rotation direction can be specified.
Shortest rotating
indexer
Positioning operation is executed to the set station. The servo motor rotates in the closest
direction from current position.
Manual
operation
mode
Indexer JOG
operation
Turning on the start signal (RYn1) makes the servo motor rotate in the direction specified by
the rotation direction specifying.
Turning off the start signal (RYn1) makes the servo motor perform positioning operation to the
closest station where the motor can decelerate to stop.
JOG operation
Executes an inching operation with the CC-Link communication based on speed data set with
parameters.
Home
position
return
mode
Torque limit
changing dog type
Home position return is performed by the Z-phase pulse count after passing proximity dog.
Home position address may be set. Home position shift distance may be set. Home position
return direction may be selected.
Automatic retract on dog back to home position/automatic stroke retract function.
Automatic torque limit changing function
Torque limit
changing data
setting type
Home position return is made without dog.
Home position may be set at any position by manual operation, etc. Home position address may
be set. Automatic torque limit changing function
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...