1 - 29
1. FUNCTIONS AND CONFIGURATION
(3) MR-J3-200TN MR-J3-200T4
Servo amplifier
I/O signal
Servo motor
(Note 2)
R S T
P
1
P
2
U V W
CN2
CN4
L
1
L
2
L
3
P
C
L
11
L
22
CN5
CN3
CN6
CC-Link
CN1
(Note 4)
MR Configurator
(Note 3)
Power supply
Molded-case circuit
breaker (MCCB)
Magnetic
contactor
(MC)
Line noise filter
(FR-BSF01)
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-(H))
Regenerative
option
(Note 1)
Battery
MR-J3BAT
Personal
computer
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
When not using power factor improving DC reactor, short P
1
and P
2
.
3. Refer to section 1.2 for the power supply specification.
4. Connectors (CNP1, CNP2, and CNP3) and appearance of MR-J3-200T servo amplifier have been changed from January 2008
production. Model name of the existing servo amplifier is changed to MR-J3-200T-RT. For MR-J3-200T-RT, refer to appendix 5.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...