9 - 12
9. GENERAL GAIN ADJUSTMENT
9.5 Differences between MELSERVO-J2-Super and MELSERVO-J3 in auto tuning
To meet higher response demands, the MELSERVO-J3 series has been changed in response level setting
range from the MR-J2-Super. The following table lists comparison of the response level setting.
MELSERVO-J2-Super MELSERVO-J3
Parameter No.3 setting
Guideline for machine resonance
frequency [Hz]
Parameter No.PA09 setting
Guideline for machine resonance
frequency [Hz]
1 10.0
2 11.3
3 12.7
1
15
4
14.3
5 16.1
6 18.1
2 20
7 20.4
8
23.0
3 25
9 25.9
4 30 10 29.2
11
32.9
5 35 12 37.0
13
41.7
6 45 14 47.0
7 55 15 52.9
16
59.6
8 70 17 67.1
18
75.6
9 85 19 85.2
20
95.9
A 105 21 108.0
22
121.7
B 130 23 137.1
C 160 24 154.4
25
173.9
D 200 26 195.9
27
220.6
E 240 28 248.5
29
279.9
F 300 30 315.3
31 355.1
32 400.0
Note that because of a slight difference in gain adjustment pattern, response may not be the same if the
resonance frequency is set to the same value.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...