4 - 27
4. SIGNALS AND WIRING
(1) Input device
POINT
Input devices assigned to the CN6 connector pins cannot be used with the
RY of CC-Link.
Device Symbol
Connector
pin No.
Functions/Applications
Forced stop
EMG
CN6-1
Forced stop (EMG) is fixed at CN6-1. Assigning this device to any other pin is
not allowed. For device details, refer to section 3.5.2 (1).
Servo-on
SON
For device details, refer to section 3.5.2 (1).
Forward rotation start
ST1
Reverse rotation start
ST2
Proximity dog
DOG
CN6-2
(Note)
Forward rotation stroke end
LSP
CN6-3
(Note)
Reverse rotation stroke end
LSN
CN6-4
(Note)
Automatic/manual selection
MD0
Temporary stop/Restart
TSTP
Internal torque limit
selection
TL1
Proportion control
PC
Gain switching
CDP
Reset RES
Clear CR
Turn CR on to clear the position control counter droop pulses on its leading
edge. The pulse width should be 10ms or more.
When the parameter No.PD22 setting is " 1", the pulses are always
cleared while CR is on.
Manual pulse generator
multiplication 1
TP0
Used to select the multiplication factor of the manual pulse generator.
When it is not selected, the parameter No.PA05 setting is made valid.
Manual pulse generator
multiplication 2
TP1
(Note)
Input
device
Manual pulse generator
multiplication factor
TP1
TP0
0
0
Parameter
No.PA05
setting
0
1
1
time
1
0
10
times
1
1
100
times
Note. 0: OFF
1: ON
Note. These are pin Nos. assigned at default.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...