17 - 39
17. SPEED CONTROL OPERATION
(4) Selection of the regenerative option
Parameter
Initial value
Unit
Setting range
No. Symbol
Name
PA02
*REG Regenerative option
0000h
Refer to the text.
POINT
To enable the parameter values, cycle the power after setting.
An incorrect setting may cause the regenerative option to burn.
If a selected regenerative option is not for use with the servo amplifier, a
parameter error (A37) occurs.
Set this parameter when using the regeneration option, brake unit, power regeneration converter, or power
regeneration common converter.
0 0
Parameter No.PA02
Selection of regenerative option
00: Regenerative option is not used
For servo amplifier of 100W, regenerative resistor is not used.
For servo amplifier of 200 to 7kW, built-in regenerative resistor is used.
Supplied regenerative resistors or regenerative option is used with
the servo amplifier of 11k to 22kW.
01: FR-BU2-(H) FR-RC-(H) FR-CV-(H)
02: MR-RB032
03: MR-RB12
04: MR-RB32
05: MR-RB30
06: MR-RB50(Cooling fan is required)
08: MR-RB31
09: MR-RB51(Cooling fan is required)
80: MR-RB1H-4
81: MR-RB3M-4(Cooling fan is required)
82: MR-RB3G-4(Cooling fan is required)
83: MR-RB5G-4(Cooling fan is required)
84: MR-RB34-4(Cooling fan is required)
85: MR-RB54-4(Cooling fan is required)
FA: When the supplied regenerative resistor is cooled by the cooling
fan to increase the ability with the servo amplifier of 11k to 22kW.
(5) Selection of servo motor speed setting unit
Parameter
Initial value
Unit
Setting range
No. Symbol
Name
PA05
*FTY Feeding function selection
0000h
Refer to the text.
POINT
To enable the parameter values, cycle the power after setting.
Select the unit of the servo motor speed.
0
0
0
Parameter No. PA05
Servo motor speed setting unit selection
0: 1r/min Unit
1: 0.1r/min Unit
Setting to "1" will be as follows.
The setting value of the servo motor speed will be limited to 6553.5 r/min.
The "Servo motor speed" status will be displayed as 0.1 r/min unit.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...