16 - 22
16. INDEXER POSITIONING OPERATION
16.2.5 Respond codes (RWrn 2)
If any of the monitor codes, instruction codes, Next station, Point table Nos./Speed command data set to the
remote register is outside the setting range, the corresponding error code is set to respond code (RWrn 2).
"0000" is set if they are normal.
0
1
2
3
Error related to instruction code/writing code
0
1
2
3
Error related to point table No./speed command data
0
1
2
3
Error related to monitor code 1/monitor code 2
Error related to next station
0
1
2
3
Code No.
Error detail
Details
Normal answer
Code error
Successfully executed.
An incorrect code No. is specified.
Code No.
Error detail
Details
Normal answer
Code error
Parameter selection error
Out of writing data range
Successfully executed.
An incorrect code No. is specified.
Unavailable parameter No. is specified.
A value out of the setting range is set.
Code No.
Error detail
Normal answer
Out of writing data range
Details
Successfully executed.
A value out of the setting range is set.
Code No.
Error detail
Normal answer
Out of writing data range
Details
Successfully executed.
A value out of the setting range is set.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...