16 - 77
16. INDEXER POSITIONING OPERATION
(5) Using absolute position detection system
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA03 *ABS Absolute position detection system
0000h
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting.
Set this parameter when using the absolute position detection system.
Selection of absolute position detection system (refer to section 16.10)
0: Used in incremental system
1: Used in absolute position detection system
Parameter No.PA03
0 0 0
(6) Servo motor speed setting unit selection
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA05 *FTY Feeding function selection
0000h
Refer to the text.
POINT
This parameter is made valid when power is switched off, then on after
setting.
Select setting units for the servo motor speed.
0
0
0
Parameter No. PA05
Servo motor speed setting unit selection
0: 1r/min unit
1: 0.1r/min unit
Setting to "1" will be as follows.
The setting value of the servo motor speed will be limited to 6553.5r/min.
The "Servo motor speed" status will be displayed as 0.1r/min unit.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...