6 - 10
6. PARAMETERS
(2) Auto tuning response (parameter No.PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting Response
Guideline for machine
resonance frequency [Hz]
Setting Response
Guideline for machine
resonance frequency [Hz]
1
Low response
10.0
17
Low response
67.1
2
11.3
18
75.6
3 12.7
19 85.2
4 14.3
20 95.9
5 16.1
21 108.0
6 18.1
22 121.7
7 20.4
23 137.1
8 23.0
24 154.4
9 25.9
25 173.9
10 29.2
26 195.9
11 32.9
27 220.6
12 37.0
28 248.5
13 41.7
29 279.9
14 47.0
30 315.3
15 52.9
31 355.1
16 Middle
response
59.6
32 Middle
response
400.0
6.1.10 In-position range
Parameter
Initial
value
Unit Setting
range
No. Symbol
Name
PA10 INP In-position
range
100
m
(pulse)
0 to 10000
Set the range, where In-position (RXn1) and Movement completion (RXnC) are output, in the command pulse
unit before calculation of the electronic gear. With the setting of parameter No.PC24, the range can be
changed to the encoder output pulse unit. Setting it to the encoder output pulse unit changes the setting unit to
pulse.
Servo motor Droop pulse
In-position range [ m]
Command pulse
Command pulse
Droop pulse
In position (RXn1)
ON
OFF
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...