4 - 46
4. SIGNALS AND WIRING
(3) HA-LP series servo motor
POINT
Refer to (2) of this section for HA-LP502 702.
(a) Wiring diagrams
Refer to section 14.9 for the cables used for wiring.
1) 200V class
MCCB
MC
MCCB
U
V
W
B1
B2
U
V
W
24VDC
CN6
M
24VDC
OHS1
L
1
L
2
L
3
BU
BV
BW
B
Servo amplifier
50m or less
Servo motor
Cooling fan
(Note 2)
(Note 5)
DOCOM
DICOM
ALM
MBR
RA1
RA2
(Note 6)
Electromagnetic
brake 24VDC
power supply
(Note 1)
(Note 3)
RA3
OHS2
TE
3-phase
200 to
230VAC
(Note 4)
Cooling fan power
supply
Servo motor
thermal
(Note 7)
RA3
Malfunction
(ALM)
RA1
(MBR)
RA2
Electromagnetic
brake interlock
Note 1. There is no polarity in electromagnetic brake terminals B1 and B2.
2. BW is not available when a 1-phase power supply is used.
3. Configure the power supply circuit which turns off the magnetic contactor after detection of servo motor thermal.
4. For the cooling fan power supply, refer to (3) (b) of this section.
5. When using a servo motor with an electromagnetic brake, assign the electromagnetic brake interlock (MBR) to an
external output signal with parameters No.PD09 to PD11.
6. Do not use the 24VDC interface power supply for the electromagnetic brake.
7. Shut off the circuit by interlocking with the emergency stop switch.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...