14 - 88
14. OPTIONS AND AUXILIARY EQUIPMENT
(c) Cable clamp fitting AERSBAN - SET
Generally, the grounding of the shielded wire may only be connected to the connector's SD terminal.
However, the effect can be increased by directly connecting the cable to a ground plate as shown below.
Install the ground plate near the servo amplifier for the encoder cable. Peel part of the cable sheath to
expose the external conductor, and press that part against the ground plate with the cable clamp. If the
cable is thin, clamp several cables in a bunch.
The clamp comes as a set with the ground plate.
[Unit: mm]
4
0
Cable clamp
(A, B)
Cable
Ground plate
cutter
cable
Strip the cable sheath of
the clamped area.
External conductor
Clamp section diagram
Outline drawing
[Unit: mm]
3
7
C A
6
6
Ground plate
2- 5 hole
mounting hole
17.5
24
0 -0
.2
B ± 0
.3
(Note) M4 screw
35
35
22
11
[Unit: mm]
30
10
24
+0.
3
0
Clamp Section diagram
L or less
Note. Screw hole for grounding. Connect it to the ground plate of the control box.
Type
A
B
C
Accessory fittings
Clamp fitting
L
AERSBAN-DSET
100
86
30
Clamp A: 2pcs.
A
70
AERSBAN-ESET
70
56
Clamp B: 1pc.
B
45
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...