7 - 20
7. MR Configurator
(1) Signal ON/OFF setting ( a), b) )
Choose the signal name or pin number and click the "ON" or "OFF" button to write the corresponding signal
status to the servo amplifier.
(2) DO forced output window closing ( c) )
Click the "Close" button to cancel the DO forced output mode and close the window.
(3) Switching to CC-Link operation mode
To switch from the test operation mode to the CC-Link operation mode, turn OFF the power of the servo
amplifier.
7.7.5 Single-step feed
POINT
The servo motor will not operate if the forced stop (EMG), forward rotation
stroke end (LSP) and reverse rotation stroke end (LSN) are off. Make
automatic ON setting to turn on these devices or make device setting to
assign them as external input signals and turn on across these signals and
SG. (Refer to section 7.6.)
The single-step feed operation cannot be used in indexer positioning
operation and speed control operation.
Operation is performed in accordance with the preset point table No.
Click "Test" on the menu bar and click "Single-step Feed" on the menu.
Clicking displays the confirmation window for switching to the test operation mode.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...