14 - 87
14. OPTIONS AND AUXILIARY EQUIPMENT
(b) Surge killer
The recommended surge killer for installation to an AC relay, AC valve, or the like near the servo
amplifier is shown below. Use this product or equivalent.
MC
SK
MC
ON
OFF
Surge killer
20cm or less
Surge killer
Relay
(Ex.) CR-50500 (Okaya Electric Industries)
Rated
voltage
AC[V]
C
[ F 20%]
R
[
30%]
Test voltage
Outline drawing [Unit: mm]
300 or more
300 or more
CR-50500
Edge soldering
Mounting band
AWG18 Twisted wire
3.6
(18.5 +
2) ±
1
(18.5 + 5) Max.
16 ± 1
6 ± 1
6 ± 1
15 ± 1
48 ± 1.5
250 0.5
50(1/2W)
Between terminals:
625VAC, 50/60Hz 60s
Between terminal
and case:
2000VAC 50/60Hz 60s
Note that a diode should be installed to a DC relay, DC valve or
the like.
Maximum voltage: Not less than 4 times the drive voltage of the
relay or the like
Maximum current: Not less than twice the drive current of the
relay or the like
Diode
RA