4 - 33
4. SIGNALS AND WIRING
4.6.3 Torque limit
CAUTION
If the torque limit is canceled during servo lock, the servo motor may suddenly
rotate according to position deviation in respect to the command position.
(1) Torque limit and torque
By setting parameter No.PA11 (forward rotation torque limit) or parameter No.PA12 (reverse rotation torque
limit), torque is always limited to the maximum value during operation. A relationship between the limit
value and servo motor torque is shown below.
0
CW direction
Max. torque
CCW direction
100
100 [%]
Torque limit value in
parameter No.PA12
Torque
Torque limit value in
parameter No.PA11
(2) Torque limit value selection
As shown below, the forward rotation torque limit (parameter No.PA11), reverse rotation torque limit
(parameter No.PA12) or internal torque limit 2 (parameter No.PC35) can be chosen using the external
torque limit selection (RY(n 2)6).
(Note) RY(n 2) 6
Limit value status
Torque limit to be enabled
CCW driving/CW
regeneration
CW driving/CCW
regeneration
0
Parameter
No.PA11
Parameter
No.PA12
1
Parameter No.PC35
Parameter No.PA11
Parameter No.PA12
Parameter No.PA11
Parameter No.PA12
Parameter No.PC35
Parameter No.PA11
Parameter No.PA12
Parameter No.PC35
Parameter No.PC35
Note. 0: OFF
1: ON
(3) Limiting torque (RXn4)
RXn4 turns on when the servo motor torque reaches the torque limited.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...