14.12 Power factor improving reactors
The power factor improving reactors improve the phase factor by increasing the form factor of servo amplifier's
input current. It can reduce the power capacity. The input power factor is improved to be about 90%. For use
with a 1-phase power supply, it may be slightly lower than 90%.
When using power factor improving reactors for two servo amplifiers or more, be sure to connect a power factor
improving reactor to each servo amplifier. If using only one power factor improving reactor, enough
improvement effect of phase factor cannot be obtained unless all servo amplifiers are operated.
R X SY T Z
Y
Z
S
T
MC
MCCB
MC
MCCB
MC
MCCB
X
R
X
Y
Z
R
S
T
X
Y
Z
R
S
T
W
C
Installation screw
W1
D1
H ±
5
D ±
5
FR-BAL-(H)
FR-BAL
FR-BAL
L
2
Blank
L
1
L
3
L
2
L
1
L
3
L
2
L
1
Servo amplifier
3-phase 200V class or
3-phase 400V class
Servo amplifier
1-phase 200V class
Servo amplifier
1-phase 100V class
3-phase
200 to
230VAC
or
3-phase
380 to
480VAC
(Note)
1-phase
200 to 230VAC
1-phase
100 to 120VAC
Note. For the 1-phase 200V to 230V power supply, Connect the power
supply to L
1
, L
2
and leave L
3
open.
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...