14 - 76
14. OPTIONS AND AUXILIARY EQUIPMENT
(2) Wires for cables
When fabricating a cable, use the wire models given in the following table or equivalent.
Table 14.3 Wires for option cables
Type Model
Length
[m(ft)]
Core size
[mm
2
]
Number
of cores
Characteristics of one core
(Note 2)
Cable
OD [mm]
Wire model
(Manufacturer)
Structure
[wires/mm]
Conductor
resistance
[ /mm]
(Note 1)
Insulator
OD
d [mm]
Encoder
cable
MR-J3ENCBL M-A1-L
2 to 10
AWG22
6
(3 pairs)
7/0.26
53
or less
1.18
7.1
(Note 3)
VSVP 7/0.26 (AWG#22 or
equivalent)-3P
KB-1655-2 (Bando Densen)
MR-J3ENCBL M-A2-L
MR-J3ENCBL M-A1-H
2 to 10
AWG22
6
(3 pairs)
70/0.08
56
or less
1.17 7.1
(Note 3)
TPE
SVP 70/0.08 (AWG#22 or
equivalent)-3P
KB-2237-2 (Bando Densen)
MR-J3ENCBL M-A2-H
MR-J3JCBL03M-A1-L
0.3 AWG26
8
(4 pairs)
30/0.08
233
or less
1.2 7.1 0.3
T/2464-1061/II A-SB 4P
26AWG (Taiyo Cabletec)
MR-J3JCBL03M-A2-L
MR-EKCBL M-L
2 to 10
AWG28
4
(2 pairs)
7/0.127
232
or less
1.18
7.0
(Note 3)
20276 composite 6-core shielded
cable
Ban-gi-shi-16395-1 (Bando
Densen)
AWG22 2 17/0.16
28.7
or less
1.50
20
30 AWG23
12
(6 pairs)
12/0.18
63.6
or less
1.2 8.2 0.3
(Note 3)
20276 VSVPAWG#23
6P
KB-0492 (Bando Densen)
MR-EKCBL M-H
2 to 10
0.2mm
2
12
(6 pairs)
40/0.08
105
or less
0.88
7.2
(Note 3) A14B2339 6P (Junkosha)
20 AWG24
12
(6 pairs)
40/0.08
105
or less
0.88 7.2
(Note 3)
TPE
SVP 40/0.08 (AWG#24 or
equivalent)-6P
KB-1928-2 (Bando Densen)
30 to 50 AWG24
14
(7 pairs)
40/0.08
105
or less
0.88 8.0
(Note 3)
TPE
SVP 40/0.08 (AWG#24 or
equivalent)-7P
KB-1929-2 (Bando Densen)
MR-J3JSCBL03M-A1-L
0.3
AWG26
8
(4 pairs)
7/0.16
146
or less
1.0 7.1 0.3
(Note 3)
VSVP 7/0.16 (AWG#26 or
equivalent)-4P
Ban-gi-shi-16822 (Bando Densen)
MR-J3JSCBL03M-A2-L
MR-J3ENSCBL M-L
(-S06)
2 to 10
AWG22
6
(3 pairs)
7/0.26
53
or less
1.18 7.1
(Note 3)
VSVP 7/0.26 (AWG#22 or
equivalent)-3P
KB-1655-2 (Bando Densen)
20
30 AWG23
12
(6 pairs)
12/0.18
63.3
or less
1.2 8.2 0.3
(Note 3)
20276 VSVPAWG#23
6P
KB-0492 (Bando Densen)
MR-J3ENSCBL M-H
(-S06)
2 to 10
AWG22
6
(3 pairs)
70/0.08
56
or less
1.17 7.1
(Note 3)
TPE
SVP 70/0.08 (AWG#22 or
equivalent)-3P
KB-2237-2 (Bando Densen)
20 to 50 AWG24
12
(6 pairs)
40/0.08
105
or less
0.88 7.2
(Note 3)
TPE
SVP 40/0.08 (AWG#24 or
equivalent)-6P
KB-1928-2 (Bando Densen)
Summary of Contents for Melservo-J3 Series MR-J3-B
Page 19: ...10 MEMO ...
Page 55: ...1 36 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 61: ...2 6 2 INSTALLATION MEMO ...
Page 179: ...4 58 4 SIGNALS AND WIRING MEMO ...
Page 241: ...5 62 5 OPERATION MEMO ...
Page 357: ...10 16 10 SPECIAL ADJUSTMENT FUNCTIONS MEMO ...
Page 385: ...11 28 11 TROUBLESHOOTING MEMO ...
Page 397: ...12 12 12 OUTLINE DRAWINGS MEMO ...
Page 755: ...17 70 17 SPEED CONTROL OPERATION MEMO ...
Page 793: ...App 38 APPENDIX MEMO ...
Page 799: ...MEMO ...