TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-202
V2.0, 2007-07
GPTA, V2.0
LTC Input Multiplexer Control Registers
Two registers, LIMCRL and LIMCRH, are assigned to each LTC group. LIMCRL controls
the connections of LTC group cells with index 0 to 3. LIMCRH controls the connections
of LTC group cells with index 4 to 7.
Note: These registers are not directly accessible and can be written and read only via
the multiplexer register array FIFO (see
LIMCRLg (g = 0-7)
Input Multiplexer Control Register for Lower Half of LTC Group g
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
LIM
EN3
LIMG3
0
LIML3
LIM
EN2
LIMG2
0
LIML2
r
rw
r
rw
r
rw
r
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
LIM
EN1
LIMG1
0
LIML1
LIM
EN0
LIMG0
0
LIML0
r
rw
r
rw
r
rw
r
rw
Field
Bits
Type Description
LIML0,
LIML1,
LIML2,
LIML3
[2:0],
[10:8],
[18:16],
[26:24]
rw
Multiplexer Line Selection
This bit field selects the input line of a LIMG that
can be selected by bit field LIMGn for LIMG output
n.
000
B
LIMG input IN0 selected
001
B
LIMG input IN1 selected
010
B
LIMG input IN2 selected
011
B
LIMG input IN3 selected
100
B
LIMG input IN4 selected
101
B
LIMG input IN5 selected
110
B
LIMG input IN6 selected
111
B
LIMG input IN7 selected