TC1796
System Units (Vol. 1 of 2)
LMB External Bus Unit
User’s Manual
13-6
V2.0, 2007-07
EBU, V2.0
13.2.8
Wait Input, WAIT
This is an input signal to the EBU that is used to dynamically insert wait states into read
or write data cycles controlled by the device on the external bus.
13.2.9
Burst Address Advance, BAA
The Burst Address Advance output, BAA, is provided for advancing the addresses
during a Burst Flash access cycle.
13.2.10
Bus Arbitration Signals, HOLD, HLDA, and BREQ
The HOLD input signal is the external bus arbitration signal that indicates to the EBU
when an external bus master requests to obtain ownership of the external bus.
The HLDA output signal is the external bus arbitration signal that indicates to a external
bus master that it has obtained ownership of the external bus from the EBU.
The BREQ output signal is the external bus arbitration signal that is asserted by the EBU
when it requests to obtain back the ownership of the external bus.
13.2.11
EBU Power Supply
The
V
DDEBU
lines provide the power supply (2.3 - 3.3 V) for the dedicated pins of the EBU
interface.