![Infineon Technologies TC1796 User Manual Download Page 1899](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371899.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-244
V2.0, 2007-07
GPTA, V2.0
LIMG0,
LIMG1,
LIMG2,
LIMG3
[6:4],
[14:12],
[22:20],
[30:28]
rw
Multiplexer Group Selection
This bit field determines the LIMGng which is
connected to input n of LTC group g.
000
B
LIMG0g selected
001
B
LIMG1g selected
011
B
LIMG3g selected
100
B
LIMG4g selected
All other combinations are reserved. If a reserved
combination of LIMGn is selected, or if
LIMENn = 0, the corresponding LIMG output is
forced to 0 level.
LIMEN0,
LIMEN1,
LIMEN2,
LIMEN3
7,
15,
23,
31
rw
Enable Multiplexer Connection
0
B
Input n is not connected to any line.
1
B
Input n is connected to the line defined by
LIMLn and LIMGn.
0
3, 11,
19, 27
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description