IDC
9
rw
Identifier Copy
0
B
The identifier of the gateway source object is
not copied.
1
B
The identifier of the gateway source object
(after storing the received frame in the source)
is copied to the gateway destination object.
Applicable only to a gateway source object; ignored
in other nodes.
DLCC
10
rw
Data Length Code Copy
0
B
Data length code is not copied.
1
B
Data length code of the gateway source object
(after storing the received frame in the source)
is copied to the gateway destination object.
Applicable only to a gateway source object; ignored
in other nodes.
DATC
11
rw
Data Copy
0
B
Data fields are not copied.
1
B
Data fields in registers MODATALn and
MODATAHn of the gateway source object
(after storing the received frame in the source)
are copied to the gateway destination.
Applicable only to a gateway source object. Ignored
in other nodes.
RXIE
16
rw
Receive Interrupt Enable
RXIE enables the message receive interrupt of
message object n. This interrupt is generated after
reception of a CAN message (independent whether
the CAN message is received directly or indirectly via
a gateway action).
0
B
Message receive interrupt is disabled.
1
B
Message receive interrupt is enabled.
Bit field MOIPRn.RXINP selects the interrupt output
line which becomes activated at this type of interrupt.