TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-173
V2.0, 2007-07
GPTA, V2.0
24.3.7
Clock Bus Register
GPTA0_CKBCTR
GPTA0 Clock Bus Control Register
(0D8
H
)
Reset Value: 0000 FFFF
H
GPTA1_CKBCTR
GPTA1 Clock Bus Control Register
(0D8
H
)
Reset Value: 0000 FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
DFALTC
DFA03
r
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DFA07
DFA06
DFA04
DFA02
rw
rw
rw
rw
Field
Bits
Type Description
DFA02
[3:0]
rw
Clock Line 2 Driving Source Selection
0
D
CLK2 is provided with
f
GPTA
1
D
CLK2 is provided with
f
GPTA
divided by 2
1
...
D
...
12
D
CLK2 is provided with
f
GPTA
divided by 2
12
13
D
CLK2 is provided with
f
GPTA
divided by 2
13
14
D
CLK2 is driven by PLL clock of other GPTA unit
15
D
CLK2 is driven by DCM3 output
DFA04
[7:4]
rw
Clock Line 4 Driving Source Selection
0
D
CLK4 is provided with
f
GPTA
1
D
CLK4 is provided with
f
GPTA
divided by 2
1
...
D
...
13
D
CLK4 is provided with
f
GPTA
divided by 2
13
14
D
CLK4 is provided with
f
GPTA
divided by 2
14
15
D
CLK4 is driven by DCM1 output
DFA06
[11:8]
rw
Clock Line 6 Driving Source Selection
0
D
CLK6 is provided with
f
GPTA
1
D
CLK6 is provided with
f
GPTA
divided by 2
1
...
D
...
13
D
CLK6 is provided with
f
GPTA
divided by 2
13
14
D
CLK6 is provided with
f
GPTA
divided by 2
14
15
D
CLK6 is driven by FPC1 output