Manage_Mux()
if ((GTCk.Event or GTCk.OIA) and GTCk.OCM != x00) then //local event
Set_Data_Out(GTCk.Output_Control_Mode.[1:0])
if (!GTCk.Bypass) then //no bypass
GTCk.Output_Mode_Out = GTCk.Output_Control_Mode.[1:0]
else
if (GTCk.Output_Control_Mode.2) then //bypass, input link enabled
GTCk.Output_Mode_Out = GTCk.Output_Mode_In
else //bypass, input link disabled
GTCk.Output_Mode_Out = 00B
endif
endif
else //no local event
if (GTCk.Output_Control_Mode.2) then //input link enabled
Set_Data_Out(GTCk.Output_Mode_In)
GTCk.Output_Mode_Out = GTCk.Output_Mode_In
else //input link disabled
Set_Data_Out(00B)
GTCk.Output_Mode_Out = 00B
endif
endif
if ( (GTCk.Enable_Of_Action) and
((GTCk.Output_Mode_In.1) or (GTCk.Output_Mode_In.0)) ) then
GTCk.Cell_Enable = 1
GTCk.Enable_Of_Action = 0
endif