TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-82
V2.0, 2007-07
MultiCAN, V2.0
TRINP
[11:8]
rw
Transfer OK Interrupt Node Pointer
TRINP selects the interrupt output line INT_Om
(m = 0-15) for a transfer OK interrupt of CAN Node x.
0000
B
Interrupt output line INT_O0 is selected.
0001
B
Interrupt output line INT_O1 is selected.
…
B
…
1110
B
Interrupt output line INT_O14 is selected.
1111
B
Interrupt output line INT_O15 is selected.
CFCINP
[15:12] rw
Frame Counter Interrupt Node Pointer
CFCINP selects the interrupt output line INT_Om
(m = 0-15) for a frame counter overflow interrupt of
CAN Node x.
0000
B
Interrupt output line INT_O0 is selected.
0001
B
Interrupt output line INT_O1 is selected.
…
B
…
1110
B
Interrupt output line INT_O14 is selected.
1111
B
Interrupt output line INT_O15 is selected.
0
[31:16] r
Reserved
Read as 0; should be written with 0.