TC1796
Peripheral Units (Vol. 2 of 2)
Synchronous Serial Interface (SSC)
User’s Manual
20-37
V2.0, 2007-07
SSC, V2.1
The Slave Select Output Control Register controls the operation of the Slave Select
Output Generation Unit.
Note: The SSOC register content is latched by each TB register write operation and
remains latched during the consecutive serial transmission.
SSOC
Slave Select Output Control Register (18
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
OEN
7
OEN
6
OEN
5
OEN
4
OEN
3
OEN
2
OEN
1
OEN
0
AOL
7
AOL
6
AOL
5
AOL
4
AOL
3
AOL
2
AOL
1
AOL
0
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
AOLn
(n = 0-7)
n
rw
Active Output Level
0
B
SLSOn is at low level during the chip select
active time
t
SLSOACT
. The high level is the
inactive level of SLSOn.
1
B
SLSO line n is at high level during the chip
select active time
t
SLSOACT
. The low level is the
inactive level of SLSOn.
OENn
(n = 0-7)
8 + n
rw
Output n Enable Control
0
B
SLSOn output is disabled; SLSOn is always at
inactive level as defined by AOLn.
1
B
SLSOn output is enabled.
0
[31:16] r
Reserved
Read as 0; should be written with 0.