TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-59
V2.0, 2007-07
MLI, V2.0
23.2.5.3 Command Frame Sent Events
A Command Frame sent event is generated when the MLI transmitter has sent a
Command Frame through pipe x (x = 0-3) that has been correctly received. Separate
status/control bits are assigned to each pipe. All four pipe related Command Frame sent
events are concatenated to one common Command Frame sent event.
Figure 23-41 Command Frame Sent Event Logic
CFSI1 Control Logic
CFSI1 Control Logic
CFSI3 Control Logic
CFSIE0
TIER
CFSIR0
CFSI0
TISR
Software
Clear
Set
MCA05898_mod
Command
Frame Sent
Event
CFSI0 Control Logic
Command
Frame Sent in
Pipe 0 Event
Command
Frame Sent in
Pipe 1 Event
Command
Frame Sent in
Pipe 2 Event
Command
Frame Sent in
Pipe 3 Event
3
To SR0
To SR1
To SR6
To SR7
.
.
.
.
.
.
CFSIP
TINPR
≥
1