TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual
5-69
V2.0, 2007-07
SCU, V2.0
5.13.3
Device Identification Registers
The SCU Module Identification Register ID contains read-only information about the
SCU module version.
SCU_ID
SCU Module Identification Register
(F0000008
H
)
Reset Value: 002C C0XX
H
31
16 15
8 7
0
MODNUM
MODTYPE
MODREV
r
r
r
Field
Bits
Type Description
MODREV
[7:0]
r
Module Revision Number
MODREV defines the module revision number. The value
of a module revision starts with 01
H
(first revision).
MODTYPE
[15:8]
r
Module Type
This bit field defines the module as a 32-bit module: C0
H
MODNUM
[31:16] r
Module Number Value
This bit field defines the module identification number for
the SCU: 002C
H
MANID
Manufacturer Identification Register
(F0000070
H
)
Reset Value: 0000 1820
H
31
16 15
5 4
0
0
MANUF
DEPT
r
r
r
Field
Bits
Type Description
DEPT
[4:0]
r
Department Identification Number
= 00
H
: indicates the Automotive & Industrial
microcontroller department within Infineon Technologies.