![Infineon Technologies TC1796 User Manual Download Page 1643](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371643.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-134
V2.0, 2007-07
MLI, V2.0
P1_IOCR4
Port 1 Input/Output Control Register 4(14
H
)
Reset Value: 2020 2020
H
31
28 27
24 23
20 19
16 15
12 11
8 7
4 3
0
PC7
0
PC6
0
PC5
0
PC4
0
rw
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PC4,
PC5,
PC6,
PC7
[7:4],
[15:12],
[23:20],
[31:28]
rw
Port Input/Output Control for Port 1 Pins 4-7
1)
Port input/output control for P1.4/TCLK0
Port input/output control for P1.5/TREADY0A
Port input/output control for P1.6/TVALID0A
Port input/output control for P1.7/TDATA0
1) Coding of bit field see
. Shaded bits and bit fields are “don’t care” for MLI I/O port control.
P1_IOCR8
Port 1 Input/Output Control Register 8(18
H
)
Reset Value: 2020 2020
H
31
28 27
24 23
20 19
16 15
12 11
8 7
4 3
0
PC11
0
PC10
0
PC9
0
PC8
0
rw
r
rw
r
rw
r
rw
r
Field
Bits
Type Description
PC8,
PC9,
PC10,
PC11
[7:4],
[15:12],
[23:20],
[31:28]
rw
Port Input/Output Control for Port 1 Pins 8-11
1)
Port input/output control for P1.8/RCLK0A
Port input/output control for P1.9/RREADY0A
Port input/output control for P1.10/RVALID0A
Port input/output control for P1.11/RDATA0A
1) Coding of bit field see
. Shaded bits and bit fields are “don’t care” for MLI I/O port control.