23.2.6.5 Command Frame Received Event
A Command Frame received event is generated if the MLI receiver has correctly
received a Command Frame through Pipe Number x (x = 0-3). Separate status/control
bits are assigned to each pipe. All four pipe related Command Frame received in pipe x
events are concatenated to one common Command Frame received event.
Figure 23-46 Command Frame Received Event Logic
Command
Frame Received
in Pipe 0 Event
CFRIE0
RIER
CFRIR0
CFRI0
RISR
Software
Clear
Set
MCA05902_mod
Command
Frame
Received
Event
CFRI0 Control Logic
≥
1
Command
Frame Received
in Pipe 1 Event
CFRI1 Control Logic
CFRI2 Control Logic
CFRI3 Control Logic
Command
Frame Received
in Pipe 2 Event
Command
Frame Received
in Pipe 3 Event
3
CFRIP
RINPR
3
To SR0
To SR1
To SR6
To SR7
.
..
.
.
.