TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-59
V2.0, 2007-07
GPTA, V2.0
One Shot Mode
In One Shot Mode (GTCCTRk.OSM = 1), a self-disable of GTCk is executed after each
GTC event (GTCCTRk.CEN = 0). The current state of a GTCk can be evaluated by
reading the control register flag bit GTCCTRk.CEN.
Note: The contents of the GTCk capture/compare register GTCXRk are write-protected
for Capture_After_Compare in Single Shot Mode. Write protection is activated
when the compare value is reached and released after a read access of register
GTCXRk occurred.
Data Output Line Control
The data output GTCkOUT can be controlled by the GTCk itself and by adjacent GTCs
with a lower order number. For this purpose, two communication signals between GTCs
are available connecting all GTCs via their M1I/M0I inputs and their M1O/ M0O outputs,
respectively (see
).
Figure 24-45 GTC Output Operation and Action Transfer
((Event and CEN) or OIA)
and (OCM != X00
B
)
MCA05954
0
FF
GTCkOUT
1
&
&
M1O
Event
OCM0
M0I
M1I
f
GPTA
OIA
BYP
OCM1
OCM2
EOA
Reset
M0O
&
CEN
OUT
Note: All bits/flags shown in this figure
are located in register GTCCTRk.
≥
1