TC1796
System Units (Vol. 1 of 2)
Direct Memory Access Controller
User’s Manual
12-60
V2.0, 2007-07
DMA, V2.0
ME0SER
16
rh
Move Engine 0 Source Error
This bit is set whenever a Move Engine 0 error occurred
during a source (read) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 0 source error has occurred.
1
B
A Move Engine 0 source error has occurred.
ME0DER
17
rh
Move Engine 0 Destination Error
This bit is set whenever a Move Engine 0 error occurred
during a destination (write) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 0 destination error has occurred.
1
B
A Move Engine 0 destination error has occurred.
ME1SER
18
rh
Move Engine 1 Source Error
This bit is set whenever a Move Engine 1 error occurred
during a source (read) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 1 source error has occurred.
1
B
A Move Engine 1 source error has occurred.
ME1DER
19
rh
Move Engine 1 Destination Error
This bit is set whenever a Move Engine 1 error occurred
during a destination (write) move of a DMA transfer, or a
request could not been serviced due to the access
protection.
0
B
No Move Engine 1 destination error has occurred.
1
B
A Move Engine 1 destination error has occurred.
FPI0ER
20
rh
SPB Error
This bit is set whenever a move that has been started by
the DMA/MLI master interface on FPI Bus interface 0
leads to an error.
0
B
No error occurred.
1
B
An error occurred on FPI Bus interface 0.
Field
Bits
Type Description