TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual
5-66
V2.0, 2007-07
SCU, V2.0
SLSPDR
16
rw
SLSO0/SLSO1 Pad Driver Strength Selection
0
B
Strong driver, sharp edge selected.
1
B
Strong driver, soft edge selected.
See also
.
SSC0PDR
17
rw
SSC0 Pad Driver Strength Selection
0
B
Strong driver, sharp edge selected
1
B
Strong driver, soft edge selected
See also
.
GIN1S
[19:18]
rw
GPTA Input1 Source Select
00
B
IN1 of GPTA input array
01
B
RxD0A
10
B
RxD0B
11
B
RxD1B
Details of GIN1S control are described in
ZERO
[23:20]
rw
Spare 0 Control Bits
This bit field contains bits that are reserved for future
SCU control tasks. Field ZERO is set to 00
H
after
reset. ZERO bits should be written with 00
H
. Reading
ZERO bits will return the value last written.
ONE
[31:24]
rw
Spare 1 Control Bits
This bit field contains bits that are reserved for future
SCU control tasks. Field ONE is set to FF
H
after
reset. ONE bits should be written with FF
H
. Reading
ONE bits will return the value last written.
0
[8:7],
[15:12]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description