![Infineon Technologies TC1796 User Manual Download Page 1818](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371818.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-163
V2.0, 2007-07
GPTA, V2.0
GPTA0_DCMTIMk (k = 0-3)
GPTA0 Duty Cycle Measurement Timer Register k
(080
H
+k*10
H
+4
H
)
Reset Value: 0000 0000
H
GPTA1_DCMTIMk (k = 0-3)
GPTA1 Duty Cycle Measurement Timer Register k
(080
H
+k*10
H
+4
H
)
Reset Value: 0000 0000
H
31
24 23
0
0
TIM
r
rwh
Field
Bits
Type Description
TIM
[23:0]
rwh
Timer Value of DCMk
0
[31:24] r
Reserved
Read as 0; should be written with 0.
GPTA0_DCMCAVk (k = 0-3)
GPTA0 Duty Cycle Measurement Capture Register k
(088
H
+k*10
H
)
Reset Value: 0000 0000
H
GPTA1_DCMCAVk (k = 0-3)
GPTA1 Duty Cycle Measurement Capture Register k
(088
H
+k*10
H
)
Reset Value: 0000 0000
H
31
24 23
0
0
CAV
r
rwh
Field
Bits
Type Description
CAV
[23:0]
rwh
Capture Value of DCMk
0
[31:24] r
Reserved
Read as 0; should be written with 0.