![Infineon Technologies TC1796 User Manual Download Page 1838](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371838.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-183
V2.0, 2007-07
GPTA, V2.0
LTCCTRk (k = 00-62)
Local Timer Cell Control Register k [Capture Mode]
(200
H
+k*8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
OUT OIA
OCM
CEN SLL ILM EOA BYP FED RED REN OSM
MOD
rh
rw
rw
rh
rh
rw
rwh
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
MOD
[1:0]
rw
Mode Control Bits
00
B
LTCk operates in Capture Mode.
01
B
LTCk operates in Compare Mode.
10
B
LTCk operates in Free-Running Timer Mode.
11
B
LTCk operates in Reset Timer Mode.
OSM
2
rw
One Shot Mode Enable
0
B
LTCk is continuously enabled.
1
B
LTCk is enabled for one event only.
REN
3
rw
Request Enable
0
B
Service request is disabled.
1
B
Service request SQSk is activated when a
- capture event has occurred
- compare event has occurred
- timer overflow has happened
depending on the operation mode selected by bit
field MOD.
RED
4
rw
Input Rising Edge Select
0
B
Capture event is not triggered by a rising edge.
1
B
Capture event is triggered by a rising edge on the
LTCkIN input line.
FED
5
rw
Input Falling Edge Select
0
B
Capture event is not triggered by a falling edge.
1
B
Capture event is triggered by a falling edge on
the LTCkIN input line.