![Infineon Technologies TC1796 User Manual Download Page 1399](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371399.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Controller Area Network (MultiCAN) Controller
User’s Manual
22-104
V2.0, 2007-07
MultiCAN, V2.0
RMM
21
rw
Transmit Object Remote Monitoring
0
B
Remote monitoring is disabled:
Identifier, IDE bit, and DLC of message object
n remain unchanged upon the reception of a
matching Remote Frame.
1
B
Remote monitoring is enabled:
Identifier, IDE bit, and DLC of a matching
Remote Frame are copied to transmit object n
in order to monitor incoming remote frames.
Bit RMM applies only to transmit objects and has no
effect on receive objects.
SDT
22
rw
Single Data Transfer
If SDT = 1 and message object n is not a FIFO base
object, then MSGVAL is cleared when this object has
taken part in a successful data transfer (receive or
transmit).
If SDT = 1 and message object n is a FIFO base
object, then MSGVAL is cleared when the pointer to
the current object CUR reaches the value of SEL in
the FIFO/Gateway Pointer Register.
With SDT = 0, bit MSGVAL is not affected.
STT
23
rw
Single Transmit Trial
If this bit is set, TXRQ is cleared on transmission
start of message object n. Thus, no transmission
retry is performed in case of transmission failure.
DLC
[27:24]
rwh
Data Length Code
Bit field determines the number of data bytes for
message object n. Valid values for DLC are 0 to 8.
A value of DLC > 8 results in a data length of 8 data
bytes.
If a frame with DLC > 8 is received, the received
value is stored in the message object.
Field
Bits
Type Description