TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-60
V2.0, 2007-07
MLI, V2.0
23.2.6
Receiver Events
The MLI receiver can generate the following MLI events:
23.2.6.1 Discarded Read Answer Event
A discarded read answer received event is generated if an Answer Frame has been
received and the read pending flag TRSTATR.RPx of its correspondent pipe is 0.
Although named “discarded”, the received data is available in the receiver data register
until it is overwritten by the next incoming data.
Figure 23-42 Discarded Read Answer Event Logic
Table 23-8
MLI Receiver Interrupts
Events
Events combined to
See
Discarded Read Answer
Discarded Read Answer
Memory Access Protection Error
Memory Access Protection/
Parity Error
Parity Error
Normal Frame Correctly Received
Normal Frame Received
Move Engine Access Terminated
Interrupt Command Frame
Interrupt Command Frame
Command Frame Received on Pipe 0 Command Frame Received
Command Frame Received on Pipe 1
Command Frame Received on Pipe 2
Command Frame Received on Pipe 3
DRAIE
RIER
DRAIR
Software
Clear
MCA05899_mod
Discarded
Read Answer
Event
DRAI
RISR
Set
3
To SR0
To SR1
To SR6
To SR7
.
.
.
.
.
.
DRAIP
RINPR