TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-268
V2.0, 2007-07
GPTA, V2.0
Note: Additional details on the clock control register functionality are described in section
“Clock Control Register CLC” on Page 3-24
of the TC1796 User’s Manual
System Units part (Volume 1).
The fractional divider register controls the clock frequency of the module timer clock
f
GPTA
. The clock frequency of
f
GPTA0
,
f
GPTA1
, and
f
LTCA2
is identical to the one of
f
GPTA
.
GPTA0_FDR
GPTA Fractional Divider Register
(00C
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
DIS
CLK
EN
HW
SUS
REQ
SUS
ACK
0
RESULT
rwh
rw
rh
rh
r
rh
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
DM
SC
SM
0
STEP
rw
rw
rw
r
rw
Field
Bits
Type Description
STEP
[9:0]
rw
Step Value
Reload or addition value for RESULT.
SM
11
rw
Suspend Mode
SM selects between granted or immediate suspend
mode.
SC
[13:12]
rw
Suspend Control
This bit field determines the behavior of the fractional
divider in suspend mode.
DM
[15:14]
rw
Divider Mode
This bit field selects normal divider mode, fractional
divider mode, and off-state.
RESULT
[25:16]
rh
Result Value
Bit field for the addition result.
SUSACK
28
rh
Suspend Mode Acknowledge
Indicates state of SPNDACK signal.
SUSREQ
29
rh
Suspend Mode Request
Indicates state of SPND signal.