![Infineon Technologies TC1796 User Manual Download Page 268](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_2055437268.webp)
TC1796
System Units (Vol. 1 of 2)
System Control Unit
User’s Manual
5-46
V2.0, 2007-07
SCU, V2.0
SCU_TCLR0
SCU Temperature Compensation 0 Level Register
(F0000058
H
)
Reset Value: 02FF FFFF
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
THCOUNT
THMAX0
rh
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
THMED0
THMIN0
rw
rw
Field
Bits
Type Description
THMIN0
[7:0]
rw
Minimum Threshold for Temp. Compensation 0
Driver level = Low or Min
THMED0
[15:8]
rw
Medium Threshold for Temp. Compensation 0
Driver level = High or Low
THMAX0
[23:16] rw
Maximum Threshold for Temp. Compensation 0
Driver level = Max or High
THCOUNT
[31:24] rh
Threshold Counter
Returns the actual count value of the counter that
counts the
f
POSC
clock pulses. THCOUNT is only
updated when temperature compensation is enabled
(TCE0 or TCE1 or both set).