![Infineon Technologies TC1796 User Manual Download Page 1144](http://html1.mh-extra.com/html/infineon-technologies/tc1796/tc1796_user-manual_20554371144.webp)
TC1796
Peripheral Units (Vol. 2 of 2)
Asynchronous/Synchronous Serial Interface (ASC)
User’s Manual
19-29
V2.0, 2007-07
ASC, V2.0
The Receive Buffer Register RBUF of the ASC module contains the receive data value
in Asynchronous Mode and Synchronous Mode.
RBUF
Receive Buffer Register
(24
H
)
Reset Value: 0000 0000
H
31
9 8
0
0
RD_VALUE
r
rh
Field
Bits
Type Description
RD_VALUE
[8:0]
rh
Receive Data Register Value
RBUF contains the received data bits and, depending
on the selected mode, the parity bit in the
asynchronous and synchronous operating modes of
the ASC.
In Asynchronous Mode, with CON.M = 011
B
(7-bit
data + parity), the received parity bit is written into
RBUF.7.
In Asynchronous Mode, with CON.M = 111
B
(8-bit
data + parity), the received parity bit is written into
RBUF.8.
0
[31:9] r
Reserved
Read as 0.