TC1796
Peripheral Units (Vol. 2 of 2)
Synchronous Serial Interface (SSC)
User’s Manual
20-42
V2.0, 2007-07
SSC, V2.1
The Transmit FIFO Control Register TXFCON (only available in SSC0) contains control
bits and bit fields that determine the operating mode of the RXFIFO.
SSC0_TXFCON
SSC0 Transmit FIFO Control Register (34
H
)
Reset Value: 0000 0100
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
0
r
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
TXFITL
0
TX
TM
EN
TXF
FLU
TXF
EN
r
rw
r
rw
w
rw
Field
Bits
Type Description
TXFEN
0
rw
TXFIFO Enable
0
B
TXFIFO is disabled
1
B
TXFIFO is enabled
Note: Resetting TXFEN automatically flushes the
TXFIFO.
TXFFLU
1
w
TXFIFO Flush
0
B
No operation
1
B
TXFIFO is flushed
Note: Setting TXFFLU clears bit field TXFFL in
register FSTAT. TXFFLU is always read as 0.
TXTMEN
2
rw
TXFIFO Transparent Mode Enable
0
B
TXFIFO Transparent Mode is disabled
1
B
TXFIFO Transparent Mode is enabled
Note: This bit is “don’t care” if the TXFIFO is disabled
(TXFEN = 0).