TC1796
System Units (Vol. 1 of 2)
Direct Memory Access Controller
User’s Manual
12-70
V2.0, 2007-07
DMA, V2.0
RBT0
[7:5]
rh
Read Buffer Trace for FPI Bus Interface 0
This bit field contains trace information from the
buffer in the FPI Bus Interface 0. In the TC1796 it
indicates the source of a bus access to the Remote
Peripheral Bus.
000
B
Reset value or bridge from FPI0 to FPI1.
001
B
DMA Move Engine 0
010
B
DMA Move Engine 1
011
B
MLI0
100
B
MLI1
Other bit combinations are reserved.
RBT0 is useful for emulation purposes. It i s not
recommended to evaluate this bit field during normal
operation of the TC1796.
ME1RS
8
rh
Move Engine 1 Read Status
0
B
Move Engine 1 is not performing a read.
1
B
Move Engine 1 is performing a read.
CH1
[11:9]
rh
Reading Channel in Move Engine 1
These bit field indicates which channel number is
currently being processed by the Move Engine 1.
ME1WS
12
rh
Move Engine 1 Write Status
0
B
Move Engine 1 is not performing a write.
1
B
Move Engine 1 is performing a write.
RBT1
[15:13]
rh
Read Buffer Trace for FPI Bus Interface 1
This bit field contains trace information from the
buffer in the FPI Bus Interface 1. In the TC1796, it
indicates the source of a bus access to the System
Peripheral Bus.
000
B
Reset value or bridge from FPI0 to FPI1.
001
B
DMA Move Engine 0
010
B
DMA Move Engine 1
011
B
MLI0
100
B
MLI1
Other bit combinations are reserved.
RBT1 is useful for emulation purposes. It i s not
recommended to evaluate this bit field during normal
operation of the TC1796.
0
[31:16]
r
Reserved
Read as 0; should be written with 0.
Field
Bits
Type Description