TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-94
V2.0, 2007-07
MLI, V2.0
NAE
8
rh
Non Acknowledge Error Flag
This bit is set when a Non-Acknowledge error condition
is detected by the MLI transmitter after a frame
transmission (see
). NAE is cleared by
hardware if a transmitted frame has been acknowledged
correctly. Bit NAE can be cleared by software via bit
SCR.CNAE.
0
[31:9]
r
Reserved
Read as 0 if read.
Field
Bits
Type Description