TC1796
Peripheral Units (Vol. 2 of 2)
General Purpose Timer Array (GPTA)
User’s Manual
24-90
V2.0, 2007-07
GPTA, V2.0
24.2.4
Input/Output Line Sharing Unit (IOLS)
The I/O Line Sharing Unit allows the 56 inputs and 112 outputs of the GPTA unit to be
routed with high flexibility between I/O lines, output lines, clock inputs, other on-chip
peripherals and other GPTA cells. The GPTA module provides a total of 56 input lines
and 112 output lines, assigned to seven I/O groups IOG[6:0] and seven output groups
OG[6:0].
Figure 24-60 Input/Output Line Sharing Unit Overview
MCA05969
INT[3:0]
Output
Multiplexer
OUT
[55:00]
GTC
Input
Multiplexer
PDL[3:0]
INT[3:0]
CLK[7:0]
LTC
Input
Multiplexer
IN
[55:00]
OUT
[111:56]
GPTA
Module
Kernel
OG0
Output Groups
OG1
OG2
OG3
OG5
OG4
OG6
56
32
32
64
56
8
8
24
4
64
56
56
56
8
IOG3
IOG2
IOG1
IOG0
IOG6
IOG5
IOG4
I/O Groups
LTCG3
LTCG2
LTCG1
LTCG0
LTC Groups
LTCG7
LTCG6
LTCG5
LTCG4
FPC[5:0]
INT[1:0]
GTCG3
GTCG2
GTCG1
GTCG0
GTC Groups