TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-88
V2.0, 2007-07
MLI, V2.0
23.4.3
Access Protection Registers
The Access Enable Register AER enables write and read operations in the
corresponding address ranges (x = 0 to 31) in addition to the global move engine enable
RCR.MOD. Each address range can be individually enabled or excluded from automatic
mode.
Note: See
for the TC1796-specific address range
definitions.
AER
Access Enable Register
(B8
H
)
Reset Value: 0000 0000
H
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
AEN
31
AEN
30
AEN
29
AEN
28
AEN
27
AEN
26
AEN
25
AEN
24
AEN
23
AEN
22
AEN
21
AEN
20
AEN
19
AEN
18
AEN
17
AEN
16
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
AEN
15
AEN
14
AEN
13
AEN
12
AEN
11
AEN
10
AEN
9
AEN
8
AEN
7
AEN
6
AEN
5
AEN
4
AEN
3
AEN
2
AEN
1
AEN
0
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
rw
Field
Bits
Type Description
AENx
(x = 0-31)
x
rw
Address Range x Enable
This bit enables the read and write capability of the
MLI move engine for address range x (x = 0-31).
0
B
Automatic MLI read and write moves to
address range x are disabled. Read/write
moves to address range x are not executed
automatically and an MLI service request can
be generated. The receiving controller’s
software has to take care about the move.
1
B
Automatic MLI read and write moves to
address range x are enabled if RCR.MOD = 1.