TC1796
System Units (Vol. 1 of 2)
On-Chip System Buses and Bus Bridges
User’s Manual
6-44
V2.0, 2007-07
Buses, V2.0
ONA2
[25:24] rw
Address 2 Trigger Control
00
B
No address 2 trigger is generated.
01
B
An address 2 trigger event is generated if the
FPI Bus address is equal to DBADR2.
10
B
An address 2 trigger event is generated if
FPI Bus address is greater or equal to
DBADR2.
11
B
same as 00
B
.
See also
ONBOS0
28
rw
Opcode Signal Status Trigger Condition
0
B
A signal status trigger is generated for all
FPI Bus opcodes except a “no operation”
opcode.
1
B
A signal status trigger is generated if the
FPI Bus opcode matches the opcode as
defined in DBBOS.OPC (see
ONBOS1
29
rw
Supervisor Mode Signal Trigger Condition
0
B
The signal status trigger generation for the
FPI Bus supervisor mode signal is disabled.
1
B
A signal status trigger is generated if the
FPI Bus supervisor mode signal state is equal
to the value of DBBOS.SVM (see
).
ONBOS2
30
rw
Write Signal Trigger Condition
0
B
The signal status trigger generation for the
FPI Bus write signal is disabled.
1
B
A signal status trigger is generated if the
FPI Bus write signal state is equal to the value
of DBBOS.WR (see
ONBOS3
31
rw
Read Signal Trigger Condition
0
B
The signal status trigger generation for the
FPI Bus read signal is disabled.
1
B
A signal status trigger is generated if the
FPI Bus read signal state is equal to the value
of DBBOS.RD (see
).
Field
Bits
Type Description