TC1796
Peripheral Units (Vol. 2 of 2)
Micro Link Interface (MLI)
User’s Manual
23-127
V2.0, 2007-07
MLI, V2.0
23.5.2
MLI Module External Registers
summarizes the module related external registers that are required for
MLI0/MLI1 programming. Details on MLI0/MLI1 related register settings are shown in the
following sections.
Figure 23-53 MLI0/MLI1 Implementation-Specific Special Function Registers
23.5.2.1 Automatic Register Overwrite
The following values are applied after reset (see
).
•
OICR = 1000 8000
H
; Setting “A” is selected
•
RCR.RCVRST = 0: the receiver is enabled for reception.
P1_IOCR0
MCA05908_mod
DMA_MLI 0SRCx
Interrupt
Registers
P1_IOCR4
P1_IOCR8
Port Registers
Clock Control
Register
DMA_MLI 1SRCy
x = 0-3
y = 0-1
DMA_CLC
P1_IOCR12
P1_PDR
P5_IOCR4
P5_PDR
P8_IOCR0
P8_IOCR4
P8_PDR
MLI 0_CLC
MLI 1_CLC